高清一区二区三区日本久,被同桌扒开腿用震蛋器折磨,极品Y荡人生白柔柔,陈佳丽人体

主營(yíng)產(chǎn)品:

便攜式焦?fàn)t紅外測(cè)溫儀,毛細(xì)吸水時(shí)間測(cè)定儀,深視力檢測(cè)儀,石油產(chǎn)品凝點(diǎn)測(cè)定儀,磷酸根分析儀,玻璃密度比較儀

產(chǎn)品資料
產(chǎn)品[

煙度計(jì)

]資料
如果您對(duì)該產(chǎn)品感興趣的話,可以 sendmsg
產(chǎn)品名稱: 煙度計(jì)
產(chǎn)品型號(hào): NTP1-HPC601
產(chǎn)品廠商: 恒奧德
產(chǎn)品文檔: 無(wú)相關(guān)文檔
簡(jiǎn)單介紹
    

煙度計(jì) 型號(hào):NTP1-HPC601 主要能點(diǎn): 體化結(jié)構(gòu)*; 采用分流式取樣術(shù)、柴油機(jī)加速、減速和穩(wěn)速時(shí)均可測(cè)量煙度; 數(shù)據(jù)自動(dòng)線性化處理,可顯示不透光度N、光吸收系數(shù)K和對(duì)應(yīng)濾紙式煙度值SF;

煙度計(jì) 的詳細(xì)介紹

煙度計(jì) 型號(hào):NTP1-HPC601

主要能點(diǎn):
     體化結(jié)構(gòu)*;
      采用分流式取樣術(shù)、柴油機(jī)加速、減速和穩(wěn)速時(shí)均可測(cè)量煙度;
      數(shù)據(jù)自動(dòng)線性化處理,可顯示不透光度N、光吸收系數(shù)K和對(duì)應(yīng)濾紙式煙度值SF;
      亮度數(shù)碼顯示;
      采用“空氣幕”術(shù)保護(hù)光學(xué)系統(tǒng)免受污染;
      檢測(cè)室自動(dòng)恒溫控制,可防冷凝而影響測(cè)試精度; 
      附自動(dòng)時(shí)間顯示,可選配轉(zhuǎn)速測(cè)量和油溫測(cè)量;
      出現(xiàn)故障自動(dòng)診斷顯示所在單元;
      配內(nèi)置打印機(jī)(或數(shù)字RS-232A接口或模擬接口)。
主要術(shù)參數(shù):

 

 
 
 
 
 
 
 
 
 
 
測(cè)量范圍              不透光度N:0~(相當(dāng)煙度值0~10FSN) 
   光吸收系數(shù)K:0~16.06m-1
示值誤差              ≤±2%(測(cè)量值)
穩(wěn)定性                自動(dòng)校零,量矩漂移≤±1%/4h
重復(fù)性                重復(fù)誤差≤±1%
分辨率                0.1%
輸出方式              數(shù)字直讀顯示,可附打印機(jī)打印煙濃度(暗度)*值,測(cè)試
                      時(shí)間、日期等??筛浇涌谂c計(jì)算機(jī)聯(lián)網(wǎng)
測(cè)量煙度溫度          70℃(自動(dòng)恒溫),當(dāng)溫度誤差≥±10%時(shí),溫度及錯(cuò)誤示
                      燈亮
環(huán)境條件              溫度0~40℃,相對(duì)濕度≤90%
電源                  AC100-240V 50Hz 消耗率150VA
外形尺寸(含支架)    160mm(深)×400mm(寬)×480mm() 
重量                  約8kg
 
Main Features:
Integrated Structural Design
Adopted a triage-type sampling technique, diesel engine acceleration, deceleration, and steady speed can be measured when the smoke
Linear automatic data processing, can be displayed opacity degrees N, light absorption coefficient K and the corresponding value of filter paper-type smoke SF
High-brightness digital display;
Use of "air curtain" technology to protect the optical system from pollution
Automatic detection of room temperature control, anti-condensation can affect the testing accuracy
Automatically attached to the time display, and optional speed measurement and oil temperature measurement
Show where the failure of automatic diagnosis unit;
Equipped with built-in printer (or digital RS-232A interface or analog interface)
 
Main technical parameters:
Test ScopeNo light transmission N:0 (equivalent to smoke value 0 ~ 10FSN)
Light absorption coefficient K0-16 .06 m-1 
Shows the value error
≤ ± 2% (measured value)
Stability
Automatic zero, volume moments drift ≤ ± 1% / 4h
Repeatability
Repeat the error ≤ ± 1%
Resolution
0.1%
Output Mode
Digital direct-reading shows that smoke concentrations can be attached
printer (dark degrees) the maximum test time, date and so on. Can be
attached to interface with the computer network
Measurement of smoke temperature
70 (automatic constant temperature), when
the temperature error of ≥ ± 10%, the temperature and the error
indicator light
Environmental conditions
Temperature 0 ~ 40
, relative humidity ≤ 90%
Power
AC100-240V  50Hz Power consumption 150VA
Dimensions (with stand)
160mm (depth) × 400mm (width) × 480mm (H)
Weight
About 8kg
 
www.51658042.com
產(chǎn)品留言
標(biāo)題
聯(lián)系人
聯(lián)系電話
內(nèi)容
驗(yàn)證碼
點(diǎn)擊換一張
注:1.可以使用快捷鍵Alt+S或Ctrl+Enter發(fā)送信息!
2.如有*,請(qǐng)您留下您的詳細(xì)聯(lián)系方式!

Copyright? 2003-2024  北京恒奧德儀器儀表有限公司版權(quán)所有
    電話:15010245973微信同號(hào)/010-51658042    傳真:    地址:    郵編: